OUTPUT
Output
Voltage |
Min. load |
Max. load |
Regulation LOAD LINE |
Output Ripple &
Noise Max.(p-p) |
+5V |
1A |
20A |
5% |
1% |
60mV |
+3.3V |
1A |
20A |
5% |
1% |
60mV |
+12V |
2A |
32A |
5% |
1% |
120mV |
-12V |
0A |
0.5A |
5% |
1% |
120mV |
+5VSB |
0.5A |
3A |
5% |
1% |
60mV |
▪ Hold up Time: 1m sec Min. AT Full Load.
▪ Rated Power: +5V&+3.3V TOTAL OUTPUT MAX.:150W; Power module Total
output power not exceed 400W
INPUT
▪ VOLTAGE RANGE/FREQUENCY: 100~240VAC +/-10% / 47 ~ 63Hz
▪ CURRENT: 7.0A(RMS) for 115VAC, 3.0A(RMS) for 230VAC.
▪ EFFICIENCY(Typ.): >80% at full load.
▪ INRUSH CURRENT: 35A Max. for 115VAC Per Module, 70A Max. for
230VAC Per Module
PROTECTION
▪ OVER LOAD: 110% ~ 150% MAX.
▪ OVER VOLTAGE: +3.3V→3.7V~4.1V ,+5V→5.7V~6.5V,+12V→13.2V~14.4V
▪ SHORT CIRCUIT: Shutdown And Latch Re-power ON
▪ Thermal Protection: The power supply shall go into thermal
protection as the case temperature exceeds 86℃(±5℃)limit. The output
shall recover only when the temperature becomes normal and AC power
is turned on again
Buzzer status
▪ No AC power to all PSU: Buzzer status=OFF
▪ AC present/Only Standby Output On: Buzzer status=OFF
▪ Power supply DC outputs ON and OK: Buzzer status=OFF
▪ Power supply failure: Buzzer status= Beeping
LED indicators
▪ No AC power to all PSU: Power system status :RED=OFF, GREEN=OFF.
Per Power Module status: ORANGE=OFF
▪ AC present/Only Standby Output On: Power system status :RED=ON,
GREEN=OFF. Per Power Module status: ORANGE=OFF
▪ Power supply DC outputs ON and OK: Power system status :RED=OFF,
GREEN=ON. Per Power Module status: ORANGE=ON
▪ Power supply failure: Power system status :RED=OFF, GREEN=
Blinking. Per Power Module status: ORANGE=OFF
FUNCTION
▪ POWER GOOD SIGNAL: Delay 200ms~500ms, TTL compatible signal
▪ POWER FAIL DELAY: >1msec. ,TTL compatible signal
▪ PS-ON (REMOTE ON/OFF): Power off: PS-ON = 2V min.; Power on: PS-ON
= 0.8V max.
▪ TTL signal: NORMAL(POWER SUPPLY ON):OUTPUT CONDITION =3V Min. ,
5.25VMax. FAILURE(POWER SUPPLY OFF): OUTPUT CONDITION =0V Min.
,1VMax.
▪ CURRENT SHARING: ON +3.3V,+5V,+12V
SAFETY
▪ SAFETY STANDARDS: TO MEET CUL UL, TUV
▪ WITHSTAND VOLTAGE: I/P-O/P:1.5KVAC FOR 1 minute. I/P-FG:1.5KVAC
FOR 1 minute
▪ ISOLATION RESISTANCE: I/P-O/P,I/P-FG,O/P-FG: 500VDC , 50M ohms
min.
EMC
▪ EMI CONDUCTION: Compliance CISPR22 Class A, FCC Class A
ENVIRONMENT
▪ Operating Temperature: 0°C to 45 °C
▪ Storage Temperature: -20°C to +70°C
▪ Operating Humidity: 5% to 95%,non-condensing
▪ Storage Humidity: 20% to 90%,non-condensing
OTHERS
▪ MTBF: Using MIL - HDBK -217F the calculated MTBF>100,000 hours at
25℃
▪ COOLINGS: 40x40x20mm x 2pcs DC fans
▪ DIMENSION: 260(D)X106(W)x41.5(H)mm