Dynapower Sure Star R1J-400I1H2A0 400W 1U Redundant Power Supply

(0)
Write review
 In stock
$569.00
  • Model
  • R1J-400I1H2A0

Description:

R1J-400I1H2A0 400W 1U Redundant Power Supply

 
 
> Input Ratings:
- Input Voltage:100~240VAC +/-10% / 47 ~ 63Hz
- Input Current:4.0A(RMS) for 115VAC, 2.0A(RMS) for 230VAC.
- Inrush Current:35A Max. for 115VAC Per Module, 70A Max. for 230VAC Per Module
 
OUTPUT
Output Voltage Min. load Max. load Regulation LOAD LINE Output Ripple &
Noise Max.(p-p)
+5V 1A 20A 5% 1% 60mV
+3.3V 1A 20A 5% 1% 60mV
+12V 2A 32A 5% 1% 120mV
-12V 0A 0.5A 5% 1% 120mV
+5VSB 0.5A 3A 5% 1% 60mV
▪ Hold up Time: 1m sec Min. AT Full Load.
▪ Rated Power: +5V&+3.3V TOTAL OUTPUT MAX.:150W; Power module Total output power not exceed 400W

 

INPUT
▪ VOLTAGE RANGE/FREQUENCY: 100~240VAC +/-10% / 47 ~ 63Hz
▪ CURRENT: 7.0A(RMS) for 115VAC, 3.0A(RMS) for 230VAC.
▪ EFFICIENCY(Typ.): >80% at full load.
▪ INRUSH CURRENT: 35A Max. for 115VAC Per Module, 70A Max. for 230VAC Per Module

PROTECTION
▪ OVER LOAD: 110% ~ 150% MAX.
▪ OVER VOLTAGE: +3.3V→3.7V~4.1V ,+5V→5.7V~6.5V,+12V→13.2V~14.4V
▪ SHORT CIRCUIT: Shutdown And Latch Re-power ON
▪ Thermal Protection: The power supply shall go into thermal protection as the case temperature exceeds 86℃(±5℃)limit. The output shall recover only when the temperature becomes normal and AC power is turned on again

Buzzer status
▪ No AC power to all PSU: Buzzer status=OFF
▪ AC present/Only Standby Output On: Buzzer status=OFF
▪ Power supply DC outputs ON and OK: Buzzer status=OFF
▪ Power supply failure: Buzzer status= Beeping

LED indicators
▪ No AC power to all PSU: Power system status :RED=OFF, GREEN=OFF. Per Power Module status: ORANGE=OFF
▪ AC present/Only Standby Output On: Power system status :RED=ON, GREEN=OFF. Per Power Module status: ORANGE=OFF
▪ Power supply DC outputs ON and OK: Power system status :RED=OFF, GREEN=ON. Per Power Module status: ORANGE=ON
▪ Power supply failure: Power system status :RED=OFF, GREEN= Blinking. Per Power Module status: ORANGE=OFF

FUNCTION
▪ POWER GOOD SIGNAL: Delay 200ms~500ms, TTL compatible signal
▪ POWER FAIL DELAY: >1msec. ,TTL compatible signal
▪ PS-ON (REMOTE ON/OFF): Power off: PS-ON = 2V min.; Power on: PS-ON = 0.8V max.
▪ TTL signal: NORMAL(POWER SUPPLY ON):OUTPUT CONDITION =3V Min. , 5.25VMax. FAILURE(POWER SUPPLY OFF): OUTPUT CONDITION =0V Min. ,1VMax.
▪ CURRENT SHARING: ON +3.3V,+5V,+12V

SAFETY
▪ SAFETY STANDARDS: TO MEET CUL UL, TUV
▪ WITHSTAND VOLTAGE: I/P-O/P:1.5KVAC FOR 1 minute. I/P-FG:1.5KVAC FOR 1 minute
▪ ISOLATION RESISTANCE: I/P-O/P,I/P-FG,O/P-FG: 500VDC , 50M ohms min.

EMC
▪ EMI CONDUCTION: Compliance CISPR22 Class A, FCC Class A

ENVIRONMENT
▪ Operating Temperature: 0°C to 45 °C
▪ Storage Temperature: -20°C to +70°C
▪ Operating Humidity: 5% to 95%,non-condensing
▪ Storage Humidity: 20% to 90%,non-condensing

OTHERS
▪ MTBF: Using MIL - HDBK -217F the calculated MTBF>100,000 hours at 25℃
▪ COOLINGS: 40x40x20mm x 2pcs DC fans
▪ DIMENSION: 260(D)X106(W)x41.5(H)mm

 

▪ 1U Size Design
▪ Hot-Swappable & Power Sharing capability
▪ Full Range AC input
▪ Low Ripple Noise
▪ High Power Density
▪ High Performance industrial Fan
▪ High Reliablity

 
20+4 Pin
P4 MB
Peripheral
FDD
8-Pin
SATA
X 1
X 1
X 5
X 1
X 1
X 3